Vehicle Detection
Search by Keyword

Search by Keyword

Vehicle Detection

We have a range of photo-electric detectors and vehicle inductive loop detectors in both mains voltage and extra low voltage models.

Inductive loop detectors are available in single channel and dual channel, with directional detection available on the dual channel units.


Where saw cutting the concrete for inductive loop coils is difficult or impossible, we can supply loop mats which are simply fixed onto the surface of the concrete.

INDUCTIVE LOOP DETECTOR MODULE - SINGLE CHANNEL

INDUCTIVE LOOP DETECTOR MODULE - SINGLE CHANNEL

INDUCTIVE LOOP DETECTOR MODULE - SINGLE CHANNEL
Click to enlarge image(s)
SELF CONTAINED INDUCTIVE LOOP DETECTOR MODULE.
This is a inductive loop detector module designed to be used in conjunction with surface or sub-surface loop coils to detect vehicle presence in a car park environment.
It can be used in conjunction with a counter module such as CT-22 to enable counting of vehicles without false counts due to detection of people as it will only detect large metal objects.
There are two relay outputs.
The presence relay output is activated when a vehicle is present on the loop coil and remains active until the vehicle drives off the coil (subject to limited presence time setting).
The pulse relay output is activated for a short duration either when a vehicle is first detected on the coil, or when the vehicle drives off the coil (selectable).
Front panel mounted DIP switches allow four different frequency settings to prevent crosstalk with adjacent loop coils and there are four available sensitivity selections.
Specifications
Input protection. Loop isolation transformer, zener diode clamping, gas discharge tube protection.
Operating modes. Limited/permanent presence, pulse on detect/undetect, automatic sensitivity boost on/off, 2 second filter on/off.
Indicators. Red LED - power on. Green LED - detecting. Green LED Flashing - loop fault.
Output configuration. 2 output relays: relay 1 = presence output, relay 2 = pulse output.
Presence output relay. Rating: 5A @ 230VAC, changeover contacts (fail-safe).
Pulse output relay. Rating: 5A @ 230VAC, changeover contacts (non-fail-safe).
Pulse output duration. Approx. 150ms.
Self tuning range. 20 - 1500uH.
Frequency adjustment. Adjustable in four steps. Loop frequency 12 - 80kHz (determined by loop geometry).
Sensitivity range. 0.5% to 0.02% inductance change in four steps.
Power requirements. 230VAC +/- 15% (PD-132) or 12 - 24V AC/DC (PD-134), 1.5VA max @ 230VAC.
Operating temperature. - 40 deg C to + 60 deg C.
Dimensions. 76mm (H) x 40mm (W) x 78mm (D).
Connector. 11 pin DIN rail mountable socket (included).
INDUCTIVE LOOP DETECTOR MODULE - DUAL CHANNEL

INDUCTIVE LOOP DETECTOR MODULE - DUAL CHANNEL

INDUCTIVE LOOP DETECTOR MODULE - DUAL CHANNEL
Click to enlarge image(s)
SELF CONTAINED INDUCTIVE LOOP DETECTOR MODULE.
This is a inductive loop detector module designed to be used in conjunction with surface or sub-surface loop coils to detect vehicle presence in a car park environment.
It can be used in conjunction with a counter module such as CT-22 to enable counting of vehicles without false counts due to detection of people as it will only detect large metal objects.
There are two normally open relay outputs, one for each channel.
In addition, the module can be set up to distinguish the direction of travel of vehicles passing over the two loop coils connected to the device. In this case, relay 1 will operate when vehicle travel is in one direction, and relay 2 will operate when vehicle travel is in the opposite direction.
Front panel mounted DIP switches allow four different frequency settings to prevent crosstalk with adjacent loop coils and there are four available sensitivity selections.
Specifications
Input protection. Loop isolation transformers, zener diode clamping, gas discharge tube protection.
Operating modes. Limited/permanent presence, pulse on detect/undetect, automatic sensitivity boost on/off, 2 second filter on/off.
Indicators. Red LED - power on. Green LED - detecting. Green LED Flashing - loop fault. (Separate green LED for each channel).
Output configuration. 2 output relays, one for each channel, or direction indication in A - B logic mode.
Presence output relays. Two relays - Rating: 5A @ 230VAC, normally open contacts (fail-safe).
Self tuning range. 20 - 1500uH.
Frequency adjustment. Adjustable in four steps. Loop frequency 12 - 80kHz (determined by loop geometry).
Sensitivity range. 0.5% to 0.02% inductance change in four steps.
Power requirements. 230VAC +/- 15% (PD-132) or 12 - 24V AC/DC (PD-134), 1.5VA max @ 230VAC.
Operating temperature. - 40 deg C to + 60 deg C.
Dimensions. 76mm (H) x 40mm (W) x 78mm (D).
Connector. 11 pin DIN rail mountable socket (included).
PHOTO ELECTRIC (PE) BEAM SET

PHOTO ELECTRIC (PE) BEAM SET

PHOTO ELECTRIC (PE) BEAM SET
Click to enlarge image(s)
PHOTO ELECTRIC SENSOR BEAM

This is an active photo electric beam with a range of 20 metres. The set consists of a photo electric transmitter and a matching receiver unit.

The transmitter sends a narrow beam of infra red light to the receiver. As long as the receiver detects the beam from the transmitter, the condition is 'normal'. If the beam is broken by an object such as a car or a person, the relay contact in the receiver changes over and remains that way until the beam is clear again.

These units can operate on wide ranging supply voltage, making them ideal for roller door safety beams, intruder detection and vehicle detection.

Please also see the custom housings suitable for mounting these beams (below).
Specifications
Power requirements. 12 - 35V dc
Output relay. Rating: 5A @ 30Vdc, single pole, changeover contact (SPDT).
Connections. Screw terminals.
Maximum operating distance. 20 metres.
Operating temperature. - 40 deg C to + 60 deg C.
Dimensions (each unit). 110mm (H) x 50mm (W) x 25mm (D).
PHOTO ELECTRIC BEAM HOUSING

PHOTO ELECTRIC BEAM HOUSING

PHOTO ELECTRIC BEAM HOUSING
Click to enlarge image(s)
PHOTO ELECTRIC SENSOR BEAM HOUSINGS

Aluminium surface mount housing for PE-20 photoelectric beams. Black paint finish with 20mm hole in bottom for conduit entry.

Price is EACH. Two required to house PE beam set (PE-20).
PREFORMED INDUCTIVE LOOP DETECTOR MAT.

PREFORMED INDUCTIVE LOOP DETECTOR MAT.

PREFORMED INDUCTIVE LOOP DETECTOR MAT.
Click to enlarge image(s)
This is a inductive loop coil preformed in a 1200 x 600 PVC mat which can be surface mounted to a concrete driveway.
This is a practical alternative to 'cut in' loops and is very simple to install using recessed head Dynabolts (included).
Please see the 'Downloads' page for a Fact Sheet on loop mat installation.
Specifications
Inductance. 120uH.
Material. 2 ply extruded PVC.
Tensile strength. 15Mpa.
Flexural strength. 110Mpa.
Hardness (Rockwell). R77.
Thermal expansion. 7.5.
Dimensions. 1200mm (L) x 40mm (W) x 7.5mm (D), chamfered edges.
Tail length. 3 metres.
Weight. 9kg.
Maximum traffic speed. 25km/hr.
Copyright © 2011 Intertechnomics (NSW) Pty Ltd